Digital Storage Oscilloscope Question & Answers May 23, 2022 By WatElectronics This article lists 75 Digital Storage Oscilloscope MCQs for engineering students. All the Digital Storage Oscilloscope Questions & Answers given below include a hint and a link wherever possible to the relevant topic. This is helpful for users who are preparing for their exams or interviews, or professionals who would like to brush up on their fundamentals on Digital Storage Oscilloscope. DSO represents Digital Storage Oscilloscope. DS Oscilloscope stores data in digital format. Frequency measurement in digital storage oscilloscopes depends on two factors: the sampling rate of the scope and the nature of the converter. Digital Storage Oscilloscopes are bright and displayed in seconds. Block diagram of Digital Storage Oscilloscope consists of the digitizer, amplifier, memory, analyzer circuit, waveform reconstruction, CRT, Horizontal amplifier, Timebase circuit, trigger, and clock circuit. An amplifier is used for amplifying the input signal, after amplification signal is passed through a digitizer which digitizes and stores the digitized signal in memory. Later conversion of digital signal to an analog signal, the signal is passed through vertical plates of CRT Tubes. The waveform on the CRT display displays data in terms of input signal and time. A/D converter is used for conversion from analog to digital signal where resolution also depends on it. The sampling theorem is used for sampling signals. DSO operates in three modes: Roll type mode, store mode, and hold or save mode. Two types of waveform reconstruction take place: Linear and Sinusoidal Interpolation. Applications of Digital Storage Oscilloscope are in the Medical field, Television, and research fields. The disadvantages of Digital Storage Oscilloscopes are complex and high cost. Speed and bandwidth are high which are more advantageous in DSO. 1). DSO represents ________? Cathode ray oscilloscope Digital storage oscilloscope Digital stand oscilloscope Day Storage oscilloscope None Hint 2). Digital signal is transduced to analog signal, and this converted signal is shown in _____? CRO DSO DOO CSO None Hint 3). ______ exists in DSO which stores digital copies of waveforms. Digital memory Analog memory Digital waveform Digital signal None Hint 4). DSO is the instrument which allows the _____ of digital waveforms. Points Slide Storage None of the above None Hint 5). DSO with Maximum quantity of frequencies are based on ______ things? Single Two Three Null None Hint 6). Frequency values depend upon _____of the extent and the converter. Bandwidth Angular frequency Sampling rate None of the above None Hint 7). Signs in DSO are extremely determined and showed in ________? Millimeters Minutes Seconds Hours None Hint 8). CRT Stands for ________? Cathode Ray Oscilloscope Cathode Ray Tube Cathode Right tube None of the above None Hint 9). DSO digitizes the _______ form of input signal. Digits Analog Computational None of the above None Hint 10). In DSO, the analog wave is turned up by _______? Oscillator Isolator Amplifiers Actuator None Hint Read more about Amplifiers. 11). The signal in DSO is computed by _____ after amplification. Digitizer Amplifier Combinator Subtractor None Hint 12) The method of converting digital signal into analog signal is done by _____? Wavefront Analyzer circuit Amplifier Oscillator None Hint Read more about Spectrum Analyzer. 13). After waveform reconstruction, the signal is related to ____ plates of CRT. Horizontal Perpendicular Inclined Hybrid None Hint 14). The Cathode Ray Tube holds ___ inserts. One Two Three Four None Hint 15). The ____ input wave is the X-Axis of Cathode Ray Tube. Horizontal Vertical Inclined Hybrid None Hint 16).The ____ input wave is the Y-Axis of Cathode Ray Tube. Vertical Parallel Inclined Hybrid None Hint 17). _______ is set off by the trigger and detect input wave. Analyzer Time base switch Oscillator Wavefront None Hint 18). Time base circuit moves to cause a wave that is a _______ signal. Triangular Ramp Rectangle None of the above None Hint 19). The output of the time base wave is expanded by a ______ amplifier. Vertical Horizontal Inclined Hybrid None Hint 20). After amplification, the parallel amplifier will issue input to the _____ plate. Vertical Parallel Inclined Hybrid None Hint Digital Storage Oscilloscope Quiz Questions and Answers. 21). Above the CRT telecast, the waveform is represented by the input wave versus _____? Amplitude Frequency Wavelength Time None Hint 22). The procedure of sampling, digitizing will accompany the _____ statement. Analyzing Sampling Organizing None of the above None Hint 23). ______ occurs when an analog signal is not properly converted into a digital signal. Detecting Brainstorm Aliasing effect Sampling None Hint 24). The Sampling rate at which samples are taken holded be greater than twice of _____ frequency. Lowest Highest Medium Slow None Hint 25).____ converter which converts analog signal to digital signal? Wavefront converter Spectrum A/D Converter D/A Converter None Hint 26). While converting from analog to digital there is a ______ in A/D converter? Increased Decreased Remains constant Null None Hint 27). In A/D Converters the type in signals are stored in _________? Analog gather registers Digital store registers Shift registers Right shift registers None Hint 28). In A/D Converters the analog type store registers are ____ at very slower rate. Write Interpreted Stop Ready None Hint 29). The output of A/D Converters are gathered in ______ store. Analog Programmed Hybrid None of the above None Hint 30).The output of A/D Converter allows operation upto _____ samples/second. 100 mega 1000mega 1mega 0.1 mega None Hint 31). DSO works in _____ modes of operation? Five Three Four One None Hint 32). In __________ mode, highly accelerated varying signals are shown on screen. Roll Store Hold None of the above None Hint 33). In ___ mode, signals are accumulated in memory. Roll Store Hold None of the above None Hint 34). In ____ mode, certain portion of signal is held and after it is accumulated in memory. Roll Store Hold None of the above None Hint 35). Hold mode is also known as ____ mode. Roll Store Hold Save None Hint Digital Storage Oscilloscope Interview Questions and Answers 36). There exists ____ types of waveform reconstruction in DSO. One Two Three Four None Hint 37). In ________ interpolation, waveform reconstruction the dots are joined by a straight line. Linear Triangular Rectangle Square None Hint 38). In ________ interpolation, waveform reconstruction the dots are joined by a sign wave. Linear Sinusoidal Rectangle Square None Hint 39). In DSO, without interpolation dots are represented outside the _____ line. Straight Curve Circular Square None Hint 40). Digital storage oscilloscope always collects ____? Wavelength Square Data Transmitter None Hint 41). Cost of a tube in DSO is _____? Maximum Cheap More Costly None Hint 42).Operating speed is ____ in DSO? More Maximum High Less None Hint 43). Resolution is also ______ in digital storage oscilloscope. Less High Least Empty None Hint 44). For high frequency signals, DSO produces _____ images. Dull Bright Dark None of the above None Hint 45).DSO checks _______ components in circuits. Faulty Active Passive Highly None Hint 46). DSO is used to analyze ___ waveforms. FET TV Transistors Amplifiers None Hint 47). Digital storage oscilloscopes have the _____ bandwidth? Lowest Highest Least Less None Hint 48). Cost of Digital storage oscilloscopes is _______? Less High Low Minimum None Hint 49). Two types of oscilloscopes exist: one analog and _______ oscilloscope? Digital Wavefront Bandwidth Interference None Hint 50). ____ can measure sound by converting that sound into voltage. Amplifier Oscilloscope Actuator Bandwidth None Hint 51). Advantage of DSO is _______? Non portable Portable Not Flexible Complex None Hint 52). DSO is used to measure _________ time intervals between signals. Capacitor Resistor Oscillator None of the above None Hint 53). Before starting the trace of signal, the _______ must be triggered first. Capacitor Resistor Oscilloscope None of the above None Hint 54). Triggering allows the DSO to _____ the signal. Stabilize Unstable Complex Random None Hint 55). ______ mode is used in the working of DSO. Single-shot Clear Equivalent None of the above None Hint 56). Technique which generates new data points by a set of discrete points is called ____? Interpolation Isolation Diversity None of the above None Hint Digital Storage Oscilloscope MCQs for Exams 57). Interpolation is used by DSO for final waves ______? Difference Visualization Absorption None of the above None Hint 58). Linear interpolation is used in the generation of ______ waves. Rectangle Pulse Triangle Straight None Hint 59). DSO has the property of flexible display with ______ storage time. Finite Infinite Maximum Null None Hint 60). Digital storage oscilloscope prevents signal _______? Amplification Degradation Interpolation Isolation None Hint 61). Digital storage oscilloscopes can analyze high-frequency ________ response. Transient Steady Circular Systematic None Hint 62). _____only records voltage fluctuations which require further diagnostics. Digital ammeter Digital voltmeter Spectrometer Analyzer None Hint 63). Highest sampling rate means fast ________ rate. Amplification Conversion Isolation Interpolation None Hint 64). Resolution ________ as the sampling rate increases. Constant Increases Decreases Infinite None Hint 65). Disadvantage of an oscilloscope is that it cannot accept data during the _____ period. Analog Digitizing Null Finite None Hint 66). At low _____ speed, it switches out to analog memory. Sweep Analyze Analog Digitize None Hint 67). Digital storage oscilloscope will allows upto ___ channels for commercial purposes. 20 30 40 50 None Hint 68). Many oscilloscopes have ______ storage capability to allow non-volatile storage of waveforms. Memory Floppy Disc Random chip None Hint 69). Linear interpolation doesn’t work well on _____waveforms. Square Pulse Sinusoidal None Of The Above None Hint 70). ______ occur between sample points while sampling technique is used in DSO. Glitches Rounds Circles Squares None Hint 71). To overcome glitches problems in DSO ___ mode of oscilloscopes are used. Tight Envelope Fixed Circular None Hint 72). In envelope mode DSO the input is sampled at every ___ sec. 200ms 200ns 200s 20ms None Hint 73). Sampling rate of DSO is controlled by the ____setting of the oscilloscope. Frequency Time Wavelength Bandwidth None Hint 74). Many input channels share common stores through a _____? Flip Flop Adder Analyzer Multiplexer None Hint 75). A 40 channel oscillator has the capability of storing ______ dots. 20000 30000 40000 25000 None Hint For More MCQs Oscilloscope Question & Answers Cathode Ray Oscilloscope Question & Answers Please fill in the comment box below. Time's up